Insulatio/protectio thermalis tuborum, ductuum aeris et vasorum (incl. cubitis, iuncturis, flangibus etc.) in apparatu refrigerationis, refrigerationis et processus ad condensationem prohibendam et ad energiam conservandam. Reductio sonitus structuralis in installationibus aquae publicae et aquae residuae.
Dimensio Kingflex | |||||||
Tcrassitudo | Wmensa 1 | Wlatitudo 1.2m | Wlatitudo 1.5m | ||||
Unciae | mm | Magnitudo (L*A) | ㎡/Volve | Magnitudo (L*A) | ㎡/Volve | Magnitudo (L*A) | ㎡/Volve |
1/4" | 6 | Triginta × unum | 30 | Triginta × 1.2 | 36 | 30 × 1.5 | 45 |
3/8" | 10 | Viginti × unum | 20 | Viginti × 1.2 | 24 | XX × I.V | 30 |
Dimidium unciae | 13 | 15 × 1 | 15 | 15 × 1.2 | 18 | 15 × 1.5 | 22.5 |
¾" | 19 | Decem × unum | 10 | 10 × 1.2 | 12 | 10 × 1.5 | 15 |
1" | 25 | Octo × unum | 8 | Octo × 1.2 | 9.6 | Octo × 1.5 | 12 |
1 1/4" | 32 | Sex × unum | 6 | Sex × 1.2 | 7.2 | Sex × 1.5 | 9 |
1 1/2" | 40 | Quinque × unum | 5 | 5 × 1.2 | 6 | 5 × 1.5 | 7.5 |
2" | 50 | 4 × 1 | 4 | 4 × 1.2 | 4.8 | 4 × 1.5 | 6 |
Data Technica Kingflex | |||
Possessio | Unitas | Valor | Methodus Probationis |
Ambitus temperaturae | °C | (-50 - 110) | GB/T 17794-1999 |
Ambitus densitatis | kg/m³ | 45-65 kg/m³ | ASTM D1667 |
Permeabilitas vaporis aquae | kg/(mspa) | ≤0.91×10﹣¹³ | DIN 52 615 BS 4370 Pars 2 1973 |
μ | - | ≥Decem milia | |
Conductivitas Thermalis | W/(mk) | ≤0.030 (-20°C) | ASTM C 518 |
|
| ≤0.032 (0°C) |
|
|
| ≤0.036 (40°C) |
|
Classificatio Ignis | - | Classis 0 et Classis 1 | BS 476 Pars 6 pars 7 |
Index Propagationis Flammae et Fumi Evoluti |
| XXV/L | ASTM E 84 |
Index Oxygenii |
| ≥36 | GB/T 2406, ISO4589 |
Absorptio Aquae, % per Volumen | % | XX% | ASTM C209 |
Stabilitas Dimensionis |
| ≤5 | ASTM C534 |
Resistentia fungorum | - | Bonus | ASTM XXI |
Resistentia ozoni |
| Bonus | GB/T 7762-1987 |
Resistentia ad UV et tempestates |
| Bonus | ASTM G23 |
1. Materia Innocua / Tuta - Compatibilis cum applicationibus in ambitus ubi probationes severae et approbationes internationales necessariae sunt ad applicationes maritimas, ferriviarias, petrochemicas et cubiculorum purorum.
2. Bona Proprietas Flammae Retardans - Cum Generatione Fumi Parva
3. Excellens Capacitas Insulationis - Ad 0°C, conductivitas thermalis semper 0.034 W/(mk) attingit.
4. Alta Resistentia Permeabilitatis Aquae - Valor WVT ≥ 12000 attingit, quod vitam utilem insulationis magnopere extendet.
Multis exhibitionibus domi et in terris externis interfuimus, multosque clientes amicosque in industria affini conciliavimus. Amicos ex toto orbe terrarum ad officinam nostram in Sinis visitandam invitamus.